Product Details:
| Minimum Order Quantity | 1 Piece |
| Usage/Application | Industrial |
| Brand | SONEL |
| Model Name/Number | MZC-310S |
| Color | ORANGE |
| Model | MZC-310S |
Lightweight for high-current measurements
The Sonel MZC-310S meter is one of the most technically advanced short-circuit loop impedance measuring instruments available on the market.
With the use of the Sonel MZC-310S meter it is possible to test short circuit loop impedance in consumer networks as well as in distribution networks protected with high-current circuit breakers. At the same time as measuring the impedance, the shock and contact voltages can be measured. Where the condition for automatic power off cannot be satisfied, the facility may be authorised to operate on the basis of the voltage criterion.
The application of the four-wire method and the flow of the measuring current in the 150/280 A pulse determine the high precision of the performed test. This single device hides a multitude of measurement capabilities, making it appreciated by specialists in many fields. The meter complies with the requirements specified in the EN 61557 standard.
Capabilities
Additional features
Reaching the areas unattainable to others
In direct vicinity of transformers or in transformer stations, where the circuits are equipped with a high current protection (fuse-links with the rating of several hundred amperes, motor circuit breakers), fault currents may reach several hundreds of kilo-amps. Measurement of fault loop impedance in such networks requires a high-current meter, which is capable of measuring ZS values at the level of single milliohms. Our patented technical solution, which uses components not available in the commercial offer (unique fault resistor), enables us to offer the meter with perfect performance in such demanding conditions.
Measurements without compromise
Commercially available fault loop impedance meters perform the measurements asymmetrically, i.e. using half-wave current. This solution introduces the transitional constant and DC constant, which does not always result in a linear behavior of the transformer during the tests. This in turn, affects the accuracy of the results. MZC-310S high-current fault loop impedance meter applies symmetrical current for measurements, which means that it uses the full wave - thanks to the advanced design of the measuring system and fault circuit.
Application
MZC-310S is used for measurements in low voltage systems (nominal voltage of 220/380 V or 230/400 V), where the prospective fault current may reach 55.7 kA (measured according to EN 61557). Low weight and high convenience of the device make it perfect for tests and measurements in large and complex manufacturing plants.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Usage/Application | Industrial |
| Brand | SONEL |
| Model Name/Number | MZC-340F |
| Color | ORANGE |
| Model | MZC-304F |
Measurement of fault loop and more
Get to know the Sonel MZC-304F compact short circuit loop impedance meter with many measurement functions.
The presented model is one of the smallest instruments available on the market intended for short circuit loop impedance measurements in 230/400 V networks and continuity of protective and equipotential connections measurements. The MZC-304F meter performs short circuit loop measurements with a resolution of 0.01 Ω, also in the case of measurements in networks protected with RCD switches. With a backlit keyboard and display, the device can be used even in low light. The device has a sealed casing with IP67 protection, which is characterised by excellent resistance and ensures smooth operation even under adverse environmental conditions.
The device meets the requirements set out in standard EN 61557.
Capabilities
Additional features
Application
The instrument is dedicated to personnel performing measurements in single and multi-family buildings, office buildings, industrial plants and any other places equipped with low voltage electrical systems. In addition, the meter is intended for maintenance personnel working on objects, where fault currents reach 4.4 kA (measured according to EN 61557). MZC-304F is also a great tool for checking circuits additionally protected by residual current devices.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Usage/Application | Industrial |
| Brand | SONEL |
| Model Name/Number | MZC-310S |
| Color | ORANGE |
| Model | MZC-310S |
Lightweight for high-current measurements
The Sonel MZC-310S meter is one of the most technically advanced short-circuit loop impedance measuring instruments available on the market.
With the use of the Sonel MZC-310S meter it is possible to test short circuit loop impedance in consumer networks as well as in distribution networks protected with high-current circuit breakers. At the same time as measuring the impedance, the shock and contact voltages can be measured. Where the condition for automatic power off cannot be satisfied, the facility may be authorised to operate on the basis of the voltage criterion.
The application of the four-wire method and the flow of the measuring current in the 150/280 A pulse determine the high precision of the performed test. This single device hides a multitude of measurement capabilities, making it appreciated by specialists in many fields. The meter complies with the requirements specified in the EN 61557 standard.
Capabilities
Additional features
Reaching the areas unattainable to others
In direct vicinity of transformers or in transformer stations, where the circuits are equipped with a high current protection (fuse-links with the rating of several hundred amperes, motor circuit breakers), fault currents may reach several hundreds of kilo-amps. Measurement of fault loop impedance in such networks requires a high-current meter, which is capable of measuring ZS values at the level of single milliohms. Our patented technical solution, which uses components not available in the commercial offer (unique fault resistor), enables us to offer the meter with perfect performance in such demanding conditions.
Measurements without compromise
Commercially available fault loop impedance meters perform the measurements asymmetrically, i.e. using half-wave current. This solution introduces the transitional constant and DC constant, which does not always result in a linear behavior of the transformer during the tests. This in turn, affects the accuracy of the results. MZC-310S high-current fault loop impedance meter applies symmetrical current for measurements, which means that it uses the full wave - thanks to the advanced design of the measuring system and fault circuit.
Application
MZC-310S is used for measurements in low voltage systems (nominal voltage of 220/380 V or 230/400 V), where the prospective fault current may reach 55.7 kA (measured according to EN 61557). Low weight and high convenience of the device make it perfect for tests and measurements in large and complex manufacturing plants.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Usage/Application | SONEL |
| Brand | SONEL |
| Model Name/Number | MZC-20E |
| Color | ORANGE |
| Model | MZC-20E |
Pocket measurements
Simple and ergonomic short circuit loop impedance meter Sonel MZC-20E.
The small MZC-20E meter allows for precise measurement of short circuit loop impedance in networks of different voltage ratings. With the use of this instrument, it is possible to test network voltage up to 440 V. The device is especially useful for installers and measuring engineers providing services in single- and multi-family buildings, office buildings, industrial plants and other buildings and facilities equipped with low-voltage electrical installations. The MZC-20E meter is also perfect for electrical maintenance services. Regardless of the area of application, in each case it guarantees smooth operation and high accuracy of the results obtained. A further advantage of this tool is its ability to operate in adverse environmental conditions, which is made possible by its very robust casing. Despite its compact dimensions, the meter performs its role flawlessly and serves well wherever precise and instant measurements are required.
Capabilities
Additional features
Application
This meter is designed for measurements on objects protected by circuit breakers with rating up to 63 A, where fault currents reach 1 kA, i.e. in housing industry, single and multi-family houses, office buildings, small factories and all other facilities that are equipped with low-voltage electrical systems. In addition, the meter is a useful tool for maintenance services.
Additional Information: